WI-3
ENGELEC
Availability: | |
---|---|
Applications
▪ Application in wind, Solar, Wind&Solar hybrid off-grid power generation station.
▪ Power supply for those unmanned regions like the coastal islands, remote mountainous regions and border posts.
Features
▪ Can be applied in wind, solar, wind&solar hybrid off-grid power generation system.
▪ Simple structure, complete function
▪ Safe and reliable by using industrial frequency transformer
▪ RS232/RS485/GPRS optional (Those with GPRS can also be monitored through App.)
▪ CE certification
Technical Parameters (3KVA & 5KVA) | ||
Model | WIT30-96 | WIT50-48 |
DC Input Parameters | ||
Rated battery voltage | 96Vdc | 48Vdc |
Input overvoltage point | 136Vdc | 68Vdc |
Input overvoltage recovery point | 132Vdc | 66Vdc |
Input undervoltage point | 86.4Vdc | 43.2Vdc |
Input undervoltage recovery point | 96Vdc | 48Vdc |
AC Output Parameters | ||
Output phase number | Three-Phase | |
Rated output power | 3KVA | 5KVA |
Rated output voltage | 380Vac | |
Rated output frequency | 50/60±0.5HZ | |
THDi | <5% | |
Efficiency | ||
Max. conversion efficiency | ≥85% | |
Protection Functions | ||
DC input overvoltage/ undervoltage protection | YES | |
DC reversed connection protection | YES | |
AC output overload protection | YES | |
AC short circuit protection | YES | |
Surge protection | YES | |
Over-temperature protection | YES | |
General Parameters | ||
Display mode | LCD | |
Isolation mode | Industrial frequency isolation | |
No-load current | ≤1A | ≤0.8A |
Environment temperature | -20℃~+40℃ | |
Humidity | 5%~95%,No condensing | |
Noise | <60dB | |
Cooling mode | Natural cooling | |
Cover protection class | IP20 | |
Product dimension(W*H*D) | 560×320×535mm | |
Product net weight | 41kg | 68kg |
Note: the listed specs are just for your reference |
Technical Parameters (10KVA-30KVA) | ||||
Model | WIT100-120 | WIT100-240 | WIT200-240 | WIT300-240 |
DC Input Parameters | ||||
Rated battery voltage | 120Vdc | 240Vdc | 240Vdc | 240Vdc |
Input overvoltage point | 170Vdc | 340Vdc | 340Vdc | 340Vdc |
Input overvoltage recovery point | 165Vdc | 330Vdc | 330Vdc | 330Vdc |
Input undervoltage point | 108Vdc | 216Vdc | 216Vdc | 216Vdc |
Input undervoltage recovery point | 120Vdc | 240Vdc | 240Vdc | 240Vdc |
AC Output Parameters | ||||
Output phase number | Three-Phase | |||
Rated output power | 10KVA | 10KVA | 20KVA | 30KVA |
Rated output voltage | 380Vac | |||
Rated output frequency | 50/60±0.5HZ | |||
THDi | <5% | |||
Efficiency | ||||
Max. conversion efficiency | ≥90% | |||
Protection Functions | ||||
DC input overvoltage/undervoltage protection | YES | |||
DC reversed connection protection | YES | |||
AC output overload protection | YES | |||
AC short circuit protection | YES | |||
Surge protection | YES | |||
Over-temperature protection | YES | |||
General Parameters | ||||
Display mode | LCD | |||
Isolation mode | Industrial frequency isolation | |||
No-load current | ≤2A | ≤1.25A | ≤2A | ≤2.5A |
Environment temperature | -20℃~+40℃ | |||
Humidity | 5%~95%,No condensing | |||
Noise | <60dB | |||
Cooling mode | Natural cooling | |||
Cover protection class | IP20 | |||
Product dimension(W*H*D) | 500×710×500mm | 600×1180×600mm | ||
Product net weight | 100kg | 200kg | 280kg | |
Note: the listed specs are just for your reference |
Applications
▪ Application in wind, Solar, Wind&Solar hybrid off-grid power generation station.
▪ Power supply for those unmanned regions like the coastal islands, remote mountainous regions and border posts.
Features
▪ Can be applied in wind, solar, wind&solar hybrid off-grid power generation system.
▪ Simple structure, complete function
▪ Safe and reliable by using industrial frequency transformer
▪ RS232/RS485/GPRS optional (Those with GPRS can also be monitored through App.)
▪ CE certification
Technical Parameters (3KVA & 5KVA) | ||
Model | WIT30-96 | WIT50-48 |
DC Input Parameters | ||
Rated battery voltage | 96Vdc | 48Vdc |
Input overvoltage point | 136Vdc | 68Vdc |
Input overvoltage recovery point | 132Vdc | 66Vdc |
Input undervoltage point | 86.4Vdc | 43.2Vdc |
Input undervoltage recovery point | 96Vdc | 48Vdc |
AC Output Parameters | ||
Output phase number | Three-Phase | |
Rated output power | 3KVA | 5KVA |
Rated output voltage | 380Vac | |
Rated output frequency | 50/60±0.5HZ | |
THDi | <5% | |
Efficiency | ||
Max. conversion efficiency | ≥85% | |
Protection Functions | ||
DC input overvoltage/ undervoltage protection | YES | |
DC reversed connection protection | YES | |
AC output overload protection | YES | |
AC short circuit protection | YES | |
Surge protection | YES | |
Over-temperature protection | YES | |
General Parameters | ||
Display mode | LCD | |
Isolation mode | Industrial frequency isolation | |
No-load current | ≤1A | ≤0.8A |
Environment temperature | -20℃~+40℃ | |
Humidity | 5%~95%,No condensing | |
Noise | <60dB | |
Cooling mode | Natural cooling | |
Cover protection class | IP20 | |
Product dimension(W*H*D) | 560×320×535mm | |
Product net weight | 41kg | 68kg |
Note: the listed specs are just for your reference |
Technical Parameters (10KVA-30KVA) | ||||
Model | WIT100-120 | WIT100-240 | WIT200-240 | WIT300-240 |
DC Input Parameters | ||||
Rated battery voltage | 120Vdc | 240Vdc | 240Vdc | 240Vdc |
Input overvoltage point | 170Vdc | 340Vdc | 340Vdc | 340Vdc |
Input overvoltage recovery point | 165Vdc | 330Vdc | 330Vdc | 330Vdc |
Input undervoltage point | 108Vdc | 216Vdc | 216Vdc | 216Vdc |
Input undervoltage recovery point | 120Vdc | 240Vdc | 240Vdc | 240Vdc |
AC Output Parameters | ||||
Output phase number | Three-Phase | |||
Rated output power | 10KVA | 10KVA | 20KVA | 30KVA |
Rated output voltage | 380Vac | |||
Rated output frequency | 50/60±0.5HZ | |||
THDi | <5% | |||
Efficiency | ||||
Max. conversion efficiency | ≥90% | |||
Protection Functions | ||||
DC input overvoltage/undervoltage protection | YES | |||
DC reversed connection protection | YES | |||
AC output overload protection | YES | |||
AC short circuit protection | YES | |||
Surge protection | YES | |||
Over-temperature protection | YES | |||
General Parameters | ||||
Display mode | LCD | |||
Isolation mode | Industrial frequency isolation | |||
No-load current | ≤2A | ≤1.25A | ≤2A | ≤2.5A |
Environment temperature | -20℃~+40℃ | |||
Humidity | 5%~95%,No condensing | |||
Noise | <60dB | |||
Cooling mode | Natural cooling | |||
Cover protection class | IP20 | |||
Product dimension(W*H*D) | 500×710×500mm | 600×1180×600mm | ||
Product net weight | 100kg | 200kg | 280kg | |
Note: the listed specs are just for your reference |